Follow us :

SV-5Q automobile exhaust gas analyzer

SV-5Q automobile exhaust gas analyzer
group name
Auto Exhaust Gas Analyzer
Min Order
1 piece
brand name
SICO Auto Diagnostic Tools
model
SW02
update time
Mon, 06 Aug 2012 14:58:42 GMT

Paramtents

  • WEIGHT 20KG

Packging & Delivery

  • Min Order1 piece

Briefing

SV-5Q automobile exhaust gas analyzer, in accordance with non-light-disguising infrared absorption method

Detailed

 

SV-5Q automobile exhaust gas analyzer


SV-5Q  automobile exhaust gas analyzer, in accordance with non-light-disguising infrared absorption method, via micro-computer analysis, directly measure the thickness of HC, CO and CO2 in the exhaust gas of vehicles and inspect the density of NO and O2 via Electrochemical sensor so as to calculate excess air coefficient λ. The analyzer introduces advanced foreign technology. It is composed of complete imported machinery cores, boasts the advantages of accuracy measurement, high endurance and speed. As an Intelligent Equipment, it is equipped with Microprocessor, LCD and Chinese language interface. Besides, it also has optional equipments such as Induction Tachometer, temperature sensor, inner Micro Printer for customers to purchase. The newly-added Storage function can detect Engine’s speed and Lubricant’s Temperature while measuring tail gas, then store and print the results.
  Besides detecting functions, its computer programs on detection under Two-speed Idle, written by us according to 《limits and measurement methods for exhaust pollutants from vehicles equipped ignition engine under two-speed idle conditions and simple driving mode conditions》,  can control the process of detection automatically. So it’s convenient to use. The analyzer has small size, light weight, storage of 500 groups’ data of exhaust gas measurement. Particularly it is suitable for check along the road. It’s utilized for auto-manufacturing factories, vehicle inspection stations and garages.
The main technical parameters:
1. Environmental temperature
Temperature:-5-40℃  humidity: ≦95%  Air pressure: 70.0-106kPa    Power:  AC  220V±10%;50Hz±1Hz
2.Measuremnt scope:HC:   0-10000 10-6(ppm)vol      CO:  0-10.0   10-2(%)vol
CO2:  0-20.0   10-2  (%)  vol O2: 0-25.0 10-2(%)vol rotate speed:0-10000rpm
NO:   0-5000          10-6(ppm)vol  oil temperature:0-120℃
3.Sampling method:tail gas: sampling directly 。The length of sampling tube: 5m,the length of probe:900mm。
Oil temperature:inserting the head of thermo scope into the staff gauge of engine lubricant, the length of which is the same as that of oil staff gauge; blocking with rubber plug to plug up engine oil from ejecting: length of lead: 5m.
Rated rpm: Non-contact measurement method. Less than 20cm to the petrol high-voltage flexible cord, measuring petrol rotate speed.
 
4.preheat time:10mins
5.resolution:CO: 0.01% vol  HC: 1ppm vol normal hexane equivalent CO2: 0.01% vol  O2: 0.01%vol
NO:  1ppm vol  rate speed: 1rpm   oil temperature: 0.1℃
6.indicated error:CO:±0.06% vol or±5% relative error.   HC:   ±12ppm vol or ±5% relative error
CO2: ±0.5% vol or ±5% relative error    O2: 0.1% vol or±5% relative error
NO:±25ppm vol or±5% relative error   rate speed:  ±10rpm(0-10000rpm) ±1% measured value (>10000rpm)
7.Stability:after preheating, zero excursion and measurement distance excursion in 4 hours should not be over the allowance value of sample value error
8.Repetitiveness: ≤1/2 of absolute of the allowed sample value error
9.Output signal: Number volume: RS232 serial massage exit.
10.Weight :15kg
11.Packing size:610x500x330mm